Electromagnetic Conductivity Analyzer

  • Filter
Created on: 21 January 2014

Electromagnetic Conductivity Transmitter MDM-135A (2-wire) Electromagnetic conductivity analyzer for field installation in a compact and rigid aluminum enclosure  Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) Alterable output range Meas. range Minimum : 0 - 2 mS/cm Maximum : 0 - 2000 mS/cm

Created on: 21 January 2014

Electromagnetic Concentration Transmitter MDM-137A (2-wire) Electromagnetic concentration analyzer for field installation in a compact and rigid aluminum enclosure   Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%)data automatically Assignable measurement range Examples of measurement ranges NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15%

Created on: 21 January 2014

Electromagnetic Conductivity Transmitter MBM-160(4-wire) Electromagnetic conductivity analyzer for field installation in a compact aluminum diecast  enclosure Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) 2-point contact signal, 2-channel output including temperature (RS-232 optional) Power source: 90 - 264VAC, 50/60Hz Meas. range Minimum: 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm

Created on: 21 January 2014

Electromagnetic Concentration Transmitter MBM-162 (4-wire) Electromagnetic concentration analyzer for field installation in a compact aluminum diecast enclosure Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%) data automatically 2-point contact signal, 2-channel output including temperature (RS-232 optional)  Examples of measurement ranges NaCl: 0~10% HCl: 30~40% H2SO4: 93~99.5% NaOH: 0~15%

Panel Type Electromagnetic Conductivity Analyzer MBM-100A Compact DIN 96 size Accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) 2-point contact signal, 4 - 20mA output (RS-232 optional)    Meas. range Minimum : 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm

Panel Type Electromagnetic Concentration Analyzer MBM-102A Compact DIN 96 size Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%) data automatically Assignable measurement range 2-point contact signal, 4 - 20mA output (RS-232 optional) Examples of measurement ranges NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15%

Created on: 21 January 2014

Toroidal type teflon detector with excellent corrosion/heat/pressure resistance  Accurate results for high conductivity corrosive solutions (such as strong acid/alkali) Types of detectors available: flow-through, immersion, pipeline insertion, etc. Meas. range Minimum: 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm

Created on: 21 January 2014

Compact toroidal, heat resistant PVC type or Teflon detector with excellent corrosion resistance are available Accurate results for high conductivity corrosive solutions (such as strong acid/alkali)  Types of detectors available: flow-through, immersion, pipeline insertion, drop-in, etc.  Meas. range Minimum : 0 - 500 μS/cm Maximum: 0 - 2000 mS/cm